B.A. MIWA, D.M. OTTEN, M.E. SCHLECHT, "High Efficiency Power Factor Correction using Interleaving Techniques", APEC'92.
Copyright - [Précédente] [Première page] [Suivante] - Home

Article : [ART073]

Titre : B.A. MIWA, D.M. OTTEN, M.E. SCHLECHT, High Efficiency Power Factor Correction using Interleaving Techniques, APEC'92.

Cité dans : [CONF001] APEC, Applied Power Electronics Conference and Exposition, juillet 2008.
Cité dans : [DIV007]  Classement par type de Congrés et de revues IEEE, avril 2003.
Auteurs : Miwa B.A.
Auteur : Otten D.M.
Auteur : Schlecht M.E. - Lab. for Electromagn. & Electron. Syst., MIT, Cambridge, MA, USA

Stockage : Thierry LEQUEU
Info. : APEC 92 New York USA / from INSPEC OCT 93 et STN Easy le lundi 1 février 1999
Info : hacheur boost entrelacé

Appears : in Applied Power Electronics Conference and Exposition, 1992. APEC '92. Conference Proceedings 1992., Seventh Annual
Date : 23-27 fevrier 1992
Pages : 557 - 568
Info : Total Pages: 858
ISBN : 0-7803-0485-3
Accession_Number : 4382043
Lien : private/ART073.pdf - 916 kB

Abstract :
A highly efficient 1.5 kW power factor correction converter for computer applications is presented. Eight boost-topology
switching cells are interleaved to meet stringent EMI input ripple specifications while operating at a very low switching
frequency (25 kHz per cell) to minimize switching losses. The result is a system with very high conversion efficiency (94%-97%,
including input bridge, bias supply, and EMI filter losses) over the 93-264 VAC input range. Key implementation details, including
discontinuous inductor current operation, a combination of linear and bang-bang control algorithms for fast dynamic load response,
and extended (100 ms) power outage ride-through capability, are described.

Subject_Terms :
switching losses minimisation; linear control; power factor correction; interleaving techniques; converter; computer applications;
boost-topology switching cells; EMI input ripple specifications; very low switching frequency; discontinuous inductor current operation;
bang-bang control algorithms; fast dynamic load response; power outage ride-through capability; 1.5 kW; 93 to 264 V; 25 kHz;
94 to 97 percent; bang-bang control; losses; power convertors; power factor correction; switching circuits

References : 15


Mise à jour le lundi 10 avril 2023 à 18 h 46 - E-mail : thierry.lequeu@gmail.com
Cette page a été produite par le programme TXT2HTM.EXE, version 10.7.3 du 27 décembre 2018.

Copyright 2023 : TOP

Les informations contenues dans cette page sont à usage strict de Thierry LEQUEU et ne doivent être utilisées ou copiées par un tiers.
Powered by www.google.fr, www.e-kart.fr, l'atelier d'Aurélie - Coiffure mixte et barbier, La Boutique Kit Elec Shop and www.lequeu.fr.